{"id":112463,"date":"2026-02-09T11:00:33","date_gmt":"2026-02-09T11:00:33","guid":{"rendered":"https:\/\/knowledge.ramtechglobal.com\/?page_id=112463"},"modified":"2026-03-26T14:46:29","modified_gmt":"2026-03-26T14:46:29","slug":"thermocable-linear-heat-detection-installation-and-operation-guide","status":"publish","type":"page","link":"https:\/\/knowledge.ramtechglobal.com\/fr\/thermocable-linear-heat-detection-installation-and-operation-guide\/","title":{"rendered":"Thermocable Linear Heat Detection &#8211; Installation and Operation Guide"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div data-parent=\"true\" class=\"vc_row row-container\" id=\"row-unique-0\"><div class=\"row triple-top-padding triple-bottom-padding single-h-padding limit-width row-parent\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_parent col-lg-3 single-internal-gutter\"><div class=\"uncol style-light sticky-element sticky-sidebar\"  ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"uncode_text_column\" ><p><a href=\"#intro\">1. Introduction<\/a><br \/>\n<a href=\"#overview\">2. System Overview<\/a><br \/>\n<a href=\"#components\">3. System Components<\/a><br \/>\n<a href=\"#characteristics\">4. Key Technical Characteristics<\/a><br \/>\n<a href=\"#planning\">5. Design and Planning Considerations<\/a><br \/>\n<a href=\"#installation\">6. Installation<\/a><br \/>\n<a href=\"#safety\">7. Safety Notices and Limitations<\/a><br \/>\n<a href=\"#related\">8. Related Documents<\/a><\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><div class=\"wpb_column pos-top pos-center align_left column_parent col-lg-9 print-content single-internal-gutter\"><div class=\"uncol style-light\"  ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_row row-internal row-container\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span><strong>Thermocable Linear Heat Detection<\/strong><\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Installation and Operation Guide<\/strong><br \/>\n<strong>Integrated with Ramtech WES3 and REACT<\/strong><\/p>\n<p><strong>Intended use:<\/strong> Technical reference and operational guidance<br \/>\n<strong>Applies to:<\/strong> ProReact EN Digital Linear Heat Detection with DSCU-EN, End of Line Unit (EOL) integrated with Ramtech systems<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"intro\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>1. Introduction<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>1.1 Purpose of this guide<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>This guide provides technical guidance on the installation intent, operation, and integration of Thermocable ProReact EN Digital Linear Heat Detection when used as part of a Ramtech fire safety solution incorporating WES3 and REACT.<\/p>\n<p>It is intended to support competent installers, commissioning engineers, site supervisors, and duty holders in understanding how the system functions and how it is typically deployed within temporary, phased, or evolving environments.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"overview\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>2. System Overview<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>2.1 Integrated system architecture<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>The solution comprises three functional layers:<\/p>\n<ul>\n<li>Detection &#8211; Thermocable ProReact EN Digital Linear Heat Detection<\/li>\n<li>On-site alarm and visibility &#8211; WES Wireless Fire Alarm System<\/li>\n<li>Remote notification and escalation &#8211; REACT Emergency Notification System<\/li>\n<\/ul>\n<p>Each layer performs a defined role and together provides continuous detection, clear on-site indication, and 24\/7 event visibility.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>2.2 Role of Thermocable within the Ramtech solution<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Thermocable provides fixed-temperature overheat detection along defined linear runs, typically installed on fa\u00e7ades, scaffolds, or temporary works.<\/p>\n<p>Thermocable does not provide evacuation or notification independently. Alarm and fault outputs from the control unit are interfaced into Ramtech systems to enable response.<\/p>\n<p>The Ramtech Linear Heat Detection system is designed for harsh external environments where traditional point detectors are unsuitable. The IP67-rated cable performs reliably in dirty, dusty, wet, and exposed conditions, making it well suited to temporary structures, fa\u00e7ades, and semi-enclosed buildings. When integrated with the Ramtech WES temporary fire system, it provides a complete end-to-end fire detection solution, with on-site alarms supported by REACT for 24\/7 monitoring, escalation, and rapid response.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>2.3 Detection, alarm, and escalation flow<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><em>[add diagram to explain this]<\/em><\/p>\n<ul>\n<li>Thermocable detects an overheat condition<\/li>\n<li>The DSCU-EN generates alarm or fault outputs<\/li>\n<li>WES3 provides on-site alarm indication<\/li>\n<li>REACT distributes alerts and escalation where specified<\/li>\n<\/ul>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"components\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>3. System Components<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>3.1 ProReact EN Digital Linear Heat Detection cable<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Detects fixed-temperature overheat conditions anywhere along its length using temperature-sensitive polymer cores.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>3.2 DSCU-EN Digital Sensor Control Unit<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Supervises the detection cable, monitors integrity, and provides alarm and fault outputs for system integration.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>3.3 EOL-EN End Of Line Unit<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>EndofLine (EOL) device is a fixed resistance component fitted at the end of each Linear Heat Detection (LHD) cable zone. Its role is to allow the DSCUEN to continuously supervise the integrity of the detection circuit. Implemented 3.6 k\u03a9 EndofLine resistor.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>3.4 WES Wireless Fire Alarm devices<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Provide wireless on-site alarm indication and manual alarm activation without reliance on fixed cabling or mains power.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>3.5 REACT Emergency Notification Platform<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Provides real-time notifications, escalation, and audit trail for alarm and fault events.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"characteristics\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>4. Key Technical Characteristics<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>4.1 ProReact EN Digital LHD cable<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li>Fixed-temperature detection using polymer core technology<\/li>\n<li>Common activation temperatures: 68 \u00b0C, 78 \u00b0C, 88 \u00b0C (model dependent)<\/li>\n<li>Non-resettable digital cable; activated sections must be removed and replaced<\/li>\n<li>Maximum detection length per DSCU-EN zone: 1,000 m (3,280 ft) including leader cable<\/li>\n<li>LSZH, UV-stable, oil-resistant outer sheath<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>4.2 DSCU-EN control unit<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li>Monitors up to two detection zones<\/li>\n<li>Built-in display shows zone status and distance to alarm point<\/li>\n<li>Volt-free alarm relays and fault outputs<\/li>\n<li>Optional RS-485 Modbus communications<\/li>\n<li>Operating voltage range: 12\u201336 Vdc<\/li>\n<li>EN54-28:2016 approved when used with ProReact EN Digital cable<\/li>\n<li>Independent and interlock (coincidence detection) modes<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>4.3 EOL-EN End of Line Unit<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li>The EOL resistor is installed at the physical end of each LHD cable zone, not at the control unit.<\/li>\n<li>If only one detection zone is used, the resistor must remain connected on the unused zone terminals to maintain supervision.<\/li>\n<li>Normal condition \u2013 cable intact, temperature below alarm threshold<\/li>\n<li>Alarm condition \u2013 heat causes the LHD cable conductors to short at the activation point<\/li>\n<li>Fault condition \u2013 cable break, disconnection, or wiring issue<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>4.4 System operating limits<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Operating limits are defined by cable length, activation temperature, environmental conditions, and power stability and must be considered during design and commissioning.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"planning\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>5. Design and Planning Considerations<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>5.1 Risk areas and detection objectives<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Thermocable is typically applied where:<\/p>\n<ul>\n<li>Linear coverage is required<\/li>\n<li>Environments are dusty, exposed, or mechanically challenging<\/li>\n<li>Point detection would be impractical or vulnerable<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>5.2 Zoning strategy<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Zoning should reflect physical layout, phased works, and alarm confidence requirements, including the use of interlock mode where appropriate.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>5.3 Power considerations<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>The DSCU-EN requires a stable power supply suitable for the site environment. Backup and inspection regimes must be defined within the project plan.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>5.4 Responsibilities<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Responsibilities for monitoring, response, maintenance, and escalation must be clearly defined and documented.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"installation\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>6. Installation<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>This section outlines the typical installation intent for Thermocable ProReact EN Digital Linear Heat Detection when integrated with Ramtech WES3 and REACT. It describes how the system is commonly deployed in practice and must be adapted to suit site conditions and the agreed fire strategy.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.1 Preparation<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Design the layout<\/strong><\/p>\n<ul>\n<li>Plan the linear heat detection (LHD) cable route to provide comprehensive coverage of defined risk areas.<\/li>\n<li>On scaffolded elevations, the cable is commonly routed to maintain coverage at each scaffolding lift, or as defined by the site fire strategy.<\/li>\n<\/ul>\n<p><strong>Compliance<\/strong><\/p>\n<ul>\n<li>Design and deployment should align with applicable standards and guidance, including EN 54-22, EN 54-28, BS 5839-1, and relevant local fire safety regulations.<\/li>\n<\/ul>\n<p><strong>Choose the right cable<\/strong><\/p>\n<ul>\n<li>Steel-braided, armoured digital LHD cable is typically used in exposed or mechanically challenging environments.<\/li>\n<li>An activation temperature of 78 \u00b0C is commonly specified, with acceptable alternatives typically ranging from 68 \u00b0C to 88 \u00b0C, subject to risk assessment and manufacturer guidance.<\/li>\n<\/ul>\n<p><strong>Clips and fasteners<\/strong><\/p>\n<ul>\n<li>Fixings are selected to remain secure under heat, weather, and environmental stress.<\/li>\n<li>Double-looped steel cable clips, steel ties, or specialist fasteners are commonly used.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.2 Cable Installation<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Spacing<\/strong><\/p>\n<ul>\n<li>Cable spacing follows manufacturer recommendations and BS 5839-1 guidance for heat detection.<\/li>\n<li>On scaffolded elevations, detection is commonly installed on alternate floors, unless otherwise required by the site fire strategy.<\/li>\n<\/ul>\n<p><strong>Fixing points<\/strong><\/p>\n<ul>\n<li>The cable is secured at regular intervals to prevent sagging or looseness over time.<\/li>\n<\/ul>\n<p><strong>Avoid tight bends<\/strong><\/p>\n<ul>\n<li>Sharp bends and tight radii are avoided, as these may damage the cable or reduce detection performance.<\/li>\n<\/ul>\n<p><strong>Environmental protection<\/strong><\/p>\n<ul>\n<li>Where required, conduit or cable covers may be used to protect the cable from weather exposure or physical damage.<\/li>\n<\/ul>\n<p><strong>Cable routing<\/strong><\/p>\n<ul>\n<li>Routing should avoid areas prone to falling debris, cutting activities, or tool damage wherever practicable.<\/li>\n<li>Clear evacuation routes should be maintained.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.3 Mounting the DSCU-EN Unit<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Location<\/strong><\/p>\n<ul>\n<li>The DSCU-EN Digital Sensor Control Unit is typically installed in a monitored location, such as a site office, security point, or designated control area.<\/li>\n<\/ul>\n<p><strong>Mounting<\/strong><\/p>\n<ul>\n<li>The unit is wall mounted in accordance with manufacturer guidance, using suitable fixings appropriate to the environment to ensure it remains secure and accessible for inspection and maintenance.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.4 Wiring, Connections, and Zoning<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li><strong>Power supply<\/strong> \u2013 The DSCU-EN operates from a 12\u201336 V DC power supply, suitable for the site environment.<\/li>\n<li><strong>Cable selection<\/strong> \u2013 Only Thermocable ProReact EN Digital Linear Heat Detection cable is used for detection zones.<\/li>\n<li><strong>Cable testing<\/strong> \u2013 Cable integrity is typically verified prior to connection.<\/li>\n<li><strong>End-of-line (EOL) unit resistor<\/strong> \u2013 It must be installed after the final detection point on the cable run.<\/li>\n<li>Each detection zone is supervised using a 3.6 k\u03a9 end-of-line resistor.<\/li>\n<li>Where only one zone is used, the resistor remains fitted to the unused zone terminals.<\/li>\n<li><strong>Cable glands<\/strong> \u2013 Cable glands are tightened to ensure a secure, moisture-resistant seal.<\/li>\n<li><strong>No T-connections<\/strong> \u2013 Detection circuits are continuous. T-connections or spur configurations are not used.<\/li>\n<li><strong>Avoid splicing<\/strong> \u2013 Splices are minimised and, where unavoidable, enclosed within manufacturer-approved junction boxes with appropriate environmental protection.<\/li>\n<li><strong>Manual call point placement<\/strong> \u2013 Wireless manual call points are typically installed at access and egress points, including scaffold lifts, and report back to a WES Connect unit in line with the site evacuation strategy.<\/li>\n<li><strong>Direct or leader cable<\/strong> \u2013 Detection cable may be connected directly to the DSCU-EN or via a leader cable where the control unit is located remotely.<\/li>\n<li><strong>Maximum zone length<\/strong> \u2013 The maximum total length per detection zone, including any leader cable, is 1,000 m (3,280 ft).<\/li>\n<li><strong>Zone inputs<\/strong> \u2013 Up to two detection zones may be connected to a single DSCU-EN in accordance with the wiring diagram.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.5 Fitting the EOL-EN Unit<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li>EndofLine (EOL) device is a fixed resistance component fitted at the end of each Linear Heat Detection (LHD) cable zone.<\/li>\n<li>Its role is to allow the DSCUEN to continuously supervise the integrity of the detection circuit.<\/li>\n<li>Implemented 3.6 k\u03a9 EndofLine resistor.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.6 Operating Mode Selection<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Independent mode<\/strong><\/p>\n<ul>\n<li>Each zone operates independently. Faults or alarms on one zone do not affect the other.<\/li>\n<\/ul>\n<p><strong>Interlock mode<\/strong><\/p>\n<ul>\n<li>Alarm output is generated only when both zones detect an overheat condition.<\/li>\n<li>Where interlock mode is used, identical cable types and activation temperatures are typically specified for both zones.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.7 Configuration and Commissioning<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li><strong>Power up<\/strong> \u2013 On power-up, the DSCU-EN displays software revision information and configuration options.<\/li>\n<li><strong>Configuration<\/strong> \u2013 New installations are typically configured using the \u201cNew Configs\u201d option.<\/li>\n<li>Existing configurations may be loaded where applicable.<\/li>\n<li><strong>Operating mode<\/strong> \u2013 Independent or Interlock mode is selected based on project requirements.<\/li>\n<li><strong>Cable type<\/strong> \u2013 Alarm temperature is selected for each zone (68 \u00b0C, 78 \u00b0C, or 88 \u00b0C).<\/li>\n<li><strong>Leader cable calibration<\/strong> \u2013 Where leader cable is used, calibration is carried out in line with on-screen prompts.<\/li>\n<li><strong>Latching outputs<\/strong> \u2013 Alarm outputs may be configured as latching, requiring manual or power reset, where specified.<\/li>\n<li><strong>Modbus setup<\/strong> \u2013 RS-485 Modbus communications may be enabled and configured where required, including address and communication parameters.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.8 Testing and Verification<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li><strong>Self-test mode<\/strong> \u2013 The self-test function is used to verify normal, alarm, and fault conditions without activating the detection cable.<\/li>\n<li><strong>Verify outputs<\/strong> \u2013 Alarm and fault outputs are verified to ensure correct operation and response by connected systems.<\/li>\n<li><strong>Exit self-test<\/strong> \u2013 The system is returned to normal operation following completion of testing.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.9 Normal Operation<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Status display<\/strong><\/p>\n<p>In normal operation, the display shows:<\/p>\n<ul>\n<li>Zone 1: OK<\/li>\n<li>Zone 2: OK<\/li>\n<\/ul>\n<p><strong>Alarm and fault indication<\/strong><br \/>\nIf triggered, the display indicates the affected zone and the distance to the activation point, along with relevant alarm or fault indicators.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.10 Maintenance and Reset<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Regular inspection<\/strong><\/p>\n<ul>\n<li>Routine inspections focus on cable integrity, fixings, connections, and overall system status.<\/li>\n<\/ul>\n<p><strong>Resetting the unit<\/strong><\/p>\n<ul>\n<li>Where required, the DSCU-EN may be reset to factory defaults via the control interface by trained personnel.<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>6.11 Documentation<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p><strong>Record keeping<\/strong><\/p>\n<ul>\n<li>Configuration settings, calibration values, test results, and zone layouts should be documented and retained for future reference.<\/li>\n<\/ul>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"safety\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>7. Safety Notices and Limitations<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>7.1 Scope and Limitations<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>This document:<\/p>\n<ul>\n<li>Describes system components, operating principles, and integration behaviour<\/li>\n<li>Does not replace Thermocable installation manuals or project-specific fire strategies<\/li>\n<li>Does not define exact cable routing, fixing methods, spacing, or evacuation procedures<\/li>\n<\/ul>\n<p>Where any discrepancy exists, manufacturer documentation and the site fire strategy take precedence.<\/p>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h5 class=\"h5\" ><span>7.2 Important Notice and Disclaimer<\/span><\/h5><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>This document provides general technical guidance only. Installation, configuration, commissioning, and maintenance must be carried out by competent persons in accordance with manufacturer documentation, applicable standards, and site-specific risk assessments.<\/p>\n<p>This guide does not define evacuation procedures or emergency response actions, which remain the responsibility of the duty holder.<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row row-internal row-container\" id=\"related\"><div class=\"row row-child\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_child col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\" ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h3 class=\"h3\" ><span>8. Related Documents<\/span><\/h3><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><\/p>\n<ul>\n<li>Thermocable ProReact EN Digital datasheets<\/li>\n<li>DSCU-EN Installation and Operation Manual<\/li>\n<li>Ramtech WES3 Operation Manual<\/li>\n<li>REACT QSG<\/li>\n<li>Troubleshooting Quick Guide<\/li>\n<\/ul>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><script id=\"script-row-unique-0\" data-row=\"script-row-unique-0\" type=\"text\/javascript\" class=\"vc_controls\">UNCODE.initRow(document.getElementById(\"row-unique-0\"));<\/script><\/div><\/div><\/div><div data-parent=\"true\" class=\"vc_row has-bg need-focus style-color-lxmt-bg row-container\" id=\"row-unique-2\"><div class=\"row double-top-padding double-bottom-padding single-h-padding limit-width row-parent\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-middle pos-center align_left column_parent col-lg-12 half-internal-gutter\"><div class=\"uncol style-light\"  ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" >\n\t<div class=\"wpb_raw_code wpb_raw_html \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<script>\nfunction exportManualPDF() {\n  var c = document.querySelector('.print-content');\n  if (!c) c = document.querySelector('[data-column-width=\"3\/4\"]');\n  if (!c) { alert('Content not found'); return; }\n\n  var cl = c.cloneNode(true);\n\n  cl.querySelectorAll('.vc_tta-panel').forEach(function(p){\n    p.classList.add('vc_active');\n  });\n\n  cl.querySelectorAll('.vc_tta-panel-body').forEach(function(b){\n    b.style.setProperty('display','block','important');\n    b.style.setProperty('height','auto','important');\n    b.style.setProperty('max-height','none','important');\n    b.style.setProperty('overflow','visible','important');\n  });\n\n  var w = window.open('', '_blank');\n  if (!w) { alert('Please allow popups to print.'); return; }\n\n  var styles =\n    '<style>' +\n    '*{box-sizing:border-box}' +\n    'body{font-family:Arial,sans-serif;padding:28px;line-height:1.6;color:#222}' +\n    '.print-header{margin-bottom:32px}' +\n    '.print-header img{max-width:220px;height:auto}' +\n    '.print-footer{margin-top:50px;padding-top:24px;border-top:1px solid #ddd;font-size:18px;color:#333}' +\n    '.print-footer a{color:#333;text-decoration:underline;font-weight:600}' +\n    'h1,h2,h3{margin:30px 0 15px;color:#333}' +\n    'h4,h5,h6{margin:20px 0 10px;color:#555}' +\n    'p,ul,ol{margin-bottom:15px}' +\n    'ul,ol{padding-left:25px}' +\n    'table{width:100%;border-collapse:collapse;margin:20px 0}' +\n    'th,td{padding:10px;border:1px solid #ddd}' +\n    'th{background:#f5f5f5}' +\n    '.vc_tta-controls-icon{display:none !important}' +\n    '.vc_tta-panel-body{display:block !important;height:auto !important;max-height:none !important;overflow:visible !important}' +\n    'img{max-width:100%;height:auto}' +\n    '@page{margin:16mm}' +\n    '@media print{body{-webkit-print-color-adjust:exact;print-color-adjust:exact}}' +\n    '<\/style>';\n\n  var header =\n    '<div class=\"print-header\">' +\n      '<img decoding=\"async\" src=\"\/wp-content\/uploads\/ramtech_logo_ob.svg\" alt=\"Ramtech\">' +\n    '<\/div>';\n\n  var footer =\n    '<div class=\"print-footer\">' +\n      '<p>' +\n        'For more information<br>' +\n        'please visit our <a href=\"https:\/\/ramtechglobal.com\/contact\/\" target=\"_blank\">contact page<\/a>.' +\n      '<\/p>' +\n    '<\/div>';\n\n  w.document.open();\n  w.document.write(\n    '<!doctype html><html><head><meta charset=\"utf-8\"><title>Print<\/title>' +\n    styles +\n    '<\/head><body>' +\n    header +\n    cl.innerHTML +\n    footer +\n    '<\/body><\/html>'\n  );\n  w.document.close();\n\n  w.focus();\n  w.onload = function(){ w.print(); };\n}\n\ndocument.addEventListener('click', function(e){\n  var btn = e.target.closest('a.js-export-manual-pdf');\n  if (!btn) return;\n  e.preventDefault();\n  exportManualPDF();\n});\n<\/script>\n\n\t\t<\/div>\n\t<\/div>\n<div class=\"vc_custom_heading_wrap \"><div class=\"heading-text el-text\" ><h4 class=\"h4 font-weight-600\" ><span>Print or save as PDF<\/span><\/h4><\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Click the button below to open a print-ready version of this page. From there, you can print it or save it as a PDF.<\/p>\n<\/div><div class=\"empty-space empty-single\" ><span class=\"empty-space-inner\"><\/span><\/div>\n<span class=\"btn-container btn-inline\" ><a role=\"button\"  href=\"\" class=\"custom-link btn border-width-0 js-export-manual-pdf btn-accent btn-circle btn-icon-left\" title=\"PRINT OR EXPORT\">PRINT OR EXPORT<\/a><\/span><\/div><\/div><\/div><\/div><\/div><script id=\"script-row-unique-2\" data-row=\"script-row-unique-2\" type=\"text\/javascript\" class=\"vc_controls\">UNCODE.initRow(document.getElementById(\"row-unique-2\"));<\/script><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>This guide provides comprehensive technical instructions for the installation, operation, and integration of Thermocable ProReact EN Digital Linear Heat Detection within Ramtech\u2019s WES3 and REACT fire safety ecosystems. It details the integrated system architecture, key technical specifications for cables and control units, and essential design considerations for challenging environments like construction sites and scaffolds. From step-by-step installation procedures and wiring configurations to commissioning, testing, and maintenance, the document ensures that technical staff can deploy a reliable, EN54-compliant heat detection solution.<\/p>","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-112463","page","type-page","status-publish","hentry","page_category-thermocable"],"_links":{"self":[{"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/pages\/112463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/comments?post=112463"}],"version-history":[{"count":38,"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/pages\/112463\/revisions"}],"predecessor-version":[{"id":112720,"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/pages\/112463\/revisions\/112720"}],"wp:attachment":[{"href":"https:\/\/knowledge.ramtechglobal.com\/fr\/wp-json\/wp\/v2\/media?parent=112463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}